Inquiry Basket Inquiry Basket (0) Item | Recent Visit History | Join Audited Suppliers
Home » Product Directory » Electrical & Electronics » Power Supply & Distribution » Power Distribution Cabinet » XGN15-12/24 SF6 Ring Main Unit

XGN15-12/24 SF6 Ring Main Unit

XGN15-12/24 SF6 Ring Main Unit
XGN15-12/24 SF6 Ring Main Unit

Trade Info

   
Trade Terms:  FOB
Payment Terms:  T/T
Price Valid Time:  From Nov 16, 2011 To Sep 21, 2012

Basic Info.

Model NO.:  XGN15-12/24
Certificate:  ISO, CCC
Export Markets:  Global

Additional Info.

Trademark:  AEP
Packing:  Plywood Case Special for Exporting
Standard:  GB, IEC
Company: Asia Electrical Power Equipment (Shenzhen) Co., Ltd.

Product Description

XGN15-12/24 SF6 ring main unit with SF6 load switch as the main switch and air insulation for whole cabinet is electric distribution automatization and compact also expandable metal clad switchgear, it character in it's simple strucuture, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users.

With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, XGN15-12/24 unit type SF6 ring main unit can completely meet the requirement of continuously variable market. It can take self-produced FL(R)N36-12/24D load break switch or ABB SFG type SF6 load break switch; Also according to user's demand can be assembled with the Ukraine BP series Vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And it can meet the requirement of "Four Controls" when matched with FTU, RTU.

This product conforms to the standards of IEC62271-100 and GB3804, 3906.11022, IEC298, 265, 129, 694, 420, 56, 529, 932.

    No.                                                           Item   Unit    Parameters
1 Rated voltage  kV     12     24
2 Rated current  A       630 / 1250 *
3 Rated frequency Hz          50 / 60
4 1min Power frequency withstand voltage  Common value kV     42    50
Across insulate distance kV     48    60
5 Lightning impulse withstand  voltage  Common value kV     75   125
Across insulate distance  kV     85   145
6 Rated short time withstand current Main loop  kA 25 / 2s 20/2s
Earth loop  kA 20 / 2s 16/2s
7 Rated withstand current ( peak)  kA     63    50
8 Rated transfer current  A   1700 1000
9 Rated active load and close circuit breaking current  A            630
10 Rated cable charge breaking current  A       50 and 10
11 Unloaded transformer breaking current  A     20    20
12 Cable charge breaking current in earthing malfunction  A     100    80
13 Rated short circuit breaking current  kA    20**  